MOBIL OIL CORP -- MOBIL 600 W CYLINDER OIL -- 9150-01-149-9116
=====================  Product Identification  =====================

Product ID:MOBIL 600 W CYLINDER OIL
MSDS Date:04/30/1998
FSC:9150
NIIN:01-149-9116
Status Code:A
MSDS Number: CKKSX
=== Responsible Party ===
Company Name:MOBIL OIL CORP
Address:3225 GALLOWS RD
City:FAIRFAX
State:VA
ZIP:22037
Country:US
Info Phone Num:800-662-4525 OR 703-849-3451
Emergency Phone Num:609-737-4411
Preparer's Name:EHS
Chemtrec Ind/Phone:(800)424-9300
CAGE:6G112
=== Contractor Identification ===
Company Name:MOBIL OIL CORP
Address:3225 GALLOWS RD
Box:City:FAIRFAX
State:VA
ZIP:22037
Country:US
Phone:800-662-4525, 856-224-4644
CAGE:6G112
Company Name:MOBIL OIL CORP, NORTH AMERICAS MARKETING AND REFINING
Address:3225 GALLOWS ROAD
Box:City:FAIRFAX
State:VA
ZIP:22037
Country:US
Phone:800-662-4525/ 856-224-4644
CAGE:3U728

=============  Composition/Information on Ingredients  =============

Ingred Name:THIS PRODUCT IS NOT FORMULATED TO CONTAIN INGREDIENTS WHICH
    HAVE EXPOSURE LIMITS ESTABLISHED BY US AGENCIES. IT IS NOT
    HAZARDOUS TO HEALTH AS DEFINED BY THE EUROPEAN UNION DANGEROUS
    SUBSTANCES/PREPARA

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:ORAL LD50 (RAT) IS >2000 MG/KG
Routes of Entry: Inhalation:NO	Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:NO SIGNIFIGANT EFFECTS EXPECTED.
Explanation of Carcinogenicity:CHRONIC MOUSE SKIN PAINTING STUDIES OF
    SEVERELY TREATED OILS SHOWED NO EVIDENCE OF CARCINOGENIC EFEFCTS.
Effects of Overexposure:NO SIGNIFICANT EFFECTS EXPECTED.
Medical Cond Aggravated by Exposure:NO DATA PROVIDED BY RESPONSIBLE
    PARTY

=======================  First Aid Measures  =======================

First Aid:EYE CONTACT: FLUSH THOROUGHLY WITH WATER. IF IRRITATION
    OCCURS, CALL A PHYSICIAN. SKIN CONTACT: WASH CONTACT AREAS WITH
    SOAP AND WATER. INHALATION: NOT EXPECTED TO BE A PROBLEM. 
    INGESTION: NOT EXPECT ED TO BE A PROBLEM WHEN INGESTED. IF
    UNCOMFORTABLE, SEEK MEDICAL ASSISTANCE.

=====================  Fire Fighting Measures  =====================

Flash Point Method:COC
Flash Point:=282.2C, 540.F
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL, WATER FOG.
Fire Fighting Procedures:WATER OR FOAM MAY CAUSE FROTHING. WATER SPRAY
    MAY BE USED TO FLUSH SPILLS AWAY FROM EXPOSURE. PREVENT RUNOFF FROM
    FIRE CONTROL OR DILUTION FROM ENTERING STREAMS, SEWERS OR DRINKING
    WATER SUPPLY. FOR F IRES IN ENCLOSED AREAS, FIRE FIGHTERS MUST USE
    SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:NONE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:ABSORB ON FIRE RETARDENT TREATED SAWDUST,
    DIATOMACEOUS EARTH, ETC. SHOVEL UP. REPORT SPILLS TO APPROPRIATE
    AUTHORITIES. PREVENT SPILL FROM ENTERING STORM SEWERS OR DRAINS &
    FROM CONTACT WITH SOIL.
Neutralizing Agent:NO DATA PROVIDED BY RESPONSIBLE PARTY

======================	Handling and Storage  ======================

Handling and Storage Precautions:NO SPECIAL PRECAUTIONS ARE NECESSARY
    BEYOUND NORMAL GOOD HYGIENE PRACTICES. DO NOT STORE IN OPEN OR
    UNLABELED CONTAINERS. STORE AWAY FROM STRONG OXIDIZING AGENTS OR
    COMBUSTIBLE MATERIALS.
Other Precautions:NO DATA PROVIDED BY RESPONSIBLE PARTY

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NO SPECIAL REQUIEMENTS UNDER ORDINARY CONDITIONS
    OF USE & WITH ADEQUATE VENTILATION.
Ventilation:NO SPECIAL REQUIREMENTS UNDER ORDINARY CONDITONS OF USE &
    WITH  ADEQUATE VENTILATION.
Protective Gloves:NO SPECIAL EQUIPMENT REQUIRED.
Eye Protection:NORMAL INDUSTRIAL EYE PROTECTION PRACTICS SHOULD BE
    EMPLOYED.
Other Protective Equipment:MFR GAVE NO INFORMATION OF MSDS.
Work Hygienic Practices:GOOD PERSONAL HYGIENE PRACTICES SHOULD ALWAYS
    BE FOLLOWED.
Supplemental Safety and Health
NO DATA PROVIDED BY RESPONSIBLE PARTY

==================  Physical/Chemical Properties  ==================

HCC:V6
Boiling Pt:=315.6C, 600.F
Melt/Freeze Pt:=-9.4C, 15.F
M.P/F.P Text:POUR POINT
Vapor Pres:<0.1 MM
Vapor Density:>3.0
Spec Gravity:0.901
Viscosity:27.5 CST @100C
Evaporation Rate & Reference:NE
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BROWN LIQUID, MILD ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS
Stability Condition to Avoid:EXTREME HEAT.
Hazardous Decomposition Products:CARBON MONOXIDE.

===================  Toxicological Information	===================

Toxicological Information:ACUTE TOXICOLOGY (RATS): PRACTICALLY
    NON-TOXIC. LD50: >2000 MG/KG. DERMAL TOXICITY (RABBITS):
    PRACTICALLY NON-TOXIC. LD50: >2000 MG/KG. INHALATION TOXICITY
    (RATS): NOT APPLICABLE-HARMFUL CONCENTRATONS  OF MISTS AND/OR
    VAPORS ARE UNLIKELY TO BE ENCOUNTERED THROUGH ANY CUSTOMARY OR
    REASONABLY FORESEEABLE HANDLING, USE OR MISUSE OF PRODUCT. EYE
    IRRITATION (RABBITS): PRACTICALLY NON-IRRITATING. DRAIZE  SCORE: 0
    OR GREATER BUT 6 OR LESS. SKIN IRRITATION (RABBITS): PRACTICALLY
    NON-IRRITATING. PRIMARY IRRITATION INDEX: 0.5 OR LESS. SUBCHRONIC
    TOXICOLOGY: EXTENSIVE EVALUATIONS OF LAB ANIMALS SHOWED NO A DVERSE
    EFFECTS.

=====================  Ecological Information  =====================

Ecological:ENVIRONMENTAL FATE AND EFFECTS: NOT ESTABLISHED.

====================  Disposal Considerations  ====================

Waste Disposal Methods:PRODUCT IS SUITABLE FOR BURNING IN AN ENCLOSED,
    CONTROLLED BURNER FOR FUEL VALUE OR DISPOSAL BY SUPERVISED
    INCINERATION. SUCH BURNING MAY BE LIMITED BY RCRA. ADDITIONALLY,
    PRODUCT IS SUITABLE FOR PROC ESSING BY AN APPROVED RECYCLING
    FACILITY OR DISPOSED OF AT AN APPROPRIATE GOVERNMENT WASTE
    FACILITY.

===================  MSDS Transport Information  ===================

Transport Information:USA DOT: NOT REGULATED BY US DOT. IMO: NOT
    REGULATED BY IMO. IATA: NOT REGULATED BY IATA.

=====================  Regulatory Information  =====================

SARA Title III Information:THIS PRODUCT CONTAINS NO CHEMICALS
    REPORTABLE UNDER SARA 313 TOXIC RELEASE PROGRAM. SARA 311/312
    REPORTABLE HAZARD CATAGORIES: NONE.
Federal Regulatory Information:GOVERNMENTAL INVENTORY STATUS: ALL
    COMPONENTS COMPLY WITH TSCA,
State Regulatory Information:OILS, LARD CAS# 8016-28-2 LISTED BY PA RTK
    AND RI RTK.

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.